Technical specification
Technical specification
Refer to Figure 5 for overall dimensions.
Measuring performance
Positional repeatability (2σ)
(At stylus tip with TP20 probe, standard force
module and 10mm stylus length)
Positional repeatability (2σ)
with 50mm extension bar (PEL1)
(At stylus tip with TP20 probe, standard force
module and 10mm stylus length)
Technical data
Range of articulation
Maximum load
Operating temperature range
Storage temperature range
Probe connector
Electrical connector
Sealing
Weight
1-14
A axis
0° to 90° in 15° increments
B axis
±180° in 15° increments
TP6 probe - no extension
TP20 or TP2 probe + 50mm
extension (PEL1)
+10°C to +40°C
-10°C to +70°C
Renishaw M8 x 1.25 x 5mm
5 pin DIN (180°)
IP30
205g (without shank)
1.5µm
2.5µm
allowed
MH8 User's Guide