• TRIM METER DOES NOT OPERATE PROPERLY [POWER TRIM/TILT TYPE ONLY]

Does the engine angle agree with the
trim meter reading?
NO
Check the meter harness A 10A fuse
(P. 18-28).
Is the fuse blown?
NO
Check the meter harness A.
Is it normal?
YES
Check the trim angle sensor
(P. 13-14).
Is it normal?
YES
Check the main wire harness.
Is it normal?
YES
Check the handle cable or remote
control cable A and B.
Are they normal?
YES
Replace the trim meter.
YES
YES
NO
NO
NO
NO
93
Temporary failure (Disappears.)
Replace the blown fuse (P. 18-28).
Repair the meter harness A or
replace it.
Replace the trim angle sensor
(P. 13-7).
Repair the main wire harness or
replace it.
Repair the handle cable or remote
control cable A and B or replace
them.