Herunterladen Inhalt Inhalt Diese Seite drucken

Omron VS mini J7 Kurzanleitung Seite 6

Compact general purpose inverter/200v class 3-phase 0.1 to 4.0kw 200v class single-phase 0.1 to 1.5kw 400v class 3-phase 0.37 to 4.0k
Vorschau ausblenden Andere Handbücher für VS mini J7:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
Checking the Name Plate
Example of 3-phase, 200VAC, 0.1kW (0.13HP)
Mounting
· Lift the cabinet by the heatsink. When moving the Inverter,
never lift it by the plastic case or the terminal covers.
Otherwise, the main unit may fall and be damaged.
· Mount the Inverter on nonflammable material (i.e., metal).
Failure to observe this caution may result in a fire.
· When mounting Inverters in an enclosure, install a fan or other cooling
device to keep the intake air temperature below 122°F (50°C)
for IP20 (open chassis type), or below 105°F(40°C) for NEMA1 (TYPE1).
Overheating may cause a fire or damage the Inverter.
· The VS mini generates heat. For effective cooling, mount it vertically.
Refer to the figure in Mounting Dimensions on section 3.
CAUTION

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cimr-j7az

Inhaltsverzeichnis