Herunterladen Inhalt Inhalt Diese Seite drucken

Type Designation; Accessories - Johnson Pump F7B-5001 Bedienungsanleitung

Flexible impeller pump with electromagnetic clutch
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
ENGLISH
4. Mount the clutch on the pump shaft
with a key (pos 15).
5. Mount o-ring (F8B) and lip seal
(spring towards the impeller) alt
mechanical seal.
6. Mount the wear plate.
7. Fasten the cam, but before doing so
apply sealing compound to cam and
screw in order to prevent leakage.

Type designation

Pump with impeller neoprene and full cam
Pump type
F7B-5001
F7B-50017
F7B-5001
F7B-50017
F8B-5001
F8B-50017
F8B-50017
F8B-50017
The Part Nos above do not include electromagnetic clutch.
Other variants on request.
Electromagnetic clutch
Voltage
12 V
24 V
12 V
24 V

Accessories

See page 20-21.
6
Part No
Connection
10-24577-13
BSP 1"
10-24577-19
NPTF 1"-11
10-24577-99
BSP 1"
10-24577-98
NPTF 1"-11
10-13022-99
BSP 1
10-13022-98
NPTF 1
10-13022-96
NPTF 1
10-13022-95
NPTF 1
Part No
Pulley
0.3454.001
2xA
0.3454.002
2xA
0.3454.003
1xB
0.3454.004
1xB
8. Lubricate the impeller with vaseline or
similar and fit it with a rotating move-
ment in the intended direction of
impeller rotation.
9. Fit the gasket alt. the o-ring before
mounting the endcover.
Seal
Lipseal
1
/
Lipseal
2
Mechanical seal
1
/
Mechanical seal
2
1
/
"
Mechanical seal
2
1
1
/
"-11
/
Mechanical seal
2
2
1
1
/
"-11
/
Mechanical seal
2
2
1
1
/
"-11
/
Mechanical seal
4
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

F8b-5017F7b-50017F8b-5001

Inhaltsverzeichnis