Herunterladen Inhalt Inhalt Diese Seite drucken

Citizen CBM1000 Bedienungsanleitung Seite 104

Vorschau ausblenden Andere Handbücher für CBM1000:
Inhaltsverzeichnis

Werbung

ESC c 5 n
[Function]
[Code]
[Range]
[Outline]
[Caution]
[Default]
[Sample Program]
Enabling/Disabling the panel switches
<1B>H<63>H<35>H<n>
0
n
255
Enabling/disabling the FEED switch.
• "n" is valid only in the lowest bit.
n0
0
1
When the panel switch is disabled with this command, the FEED
switch is also disabled. Therefore, the paper cannot be fed by
operating the FEED switch. Regardless of the setting of this
command, the FEED switch is always enable while the switch is
being waited for at the time of macro execution.
n = 0
LPRINT CHR$(&H1B) + "c5" + CHR$(0);
LPRINT CHR$(&H1B) + "c5" + CHR$(1);
Condition
FEED switch valid
FEED switch invalid
— 86 —
← When enabling the FEED switch
← When disabling the FEED switch