Set temperature to Zone 1 : The maximum temperature at which ice and snow
should be melted can be set here. Set the required temperature and press OK.
Set temperature to Zone 2 : The maximum temperature at which ice and snow
should be melted. Set the required temperature and press OK.
Afterrun time Zone 1 : An afterheat duration of between 0 and 6 hours can be
set here. The system will continue to provide heat for the specified time after the
moisture/temperature signal has been eliminated by a heating cycle. Use the
encoder button to set the required afterrun time and press OK.
Afterrun time Zone 2 : An afterheat duration of between 0 and 6 hours can be
set here. Use the encoder button to set the required afterrun time and press OK.
Zone 1 temperature can be calibrated here. The temperature recorded by the
ETOG sensor can be adjusted so that the exact temperature is displayed on
ETO2. Measure the temperature beside the sensor using a thermometer. Adjust
the necessary offset using the encoder button. Press OK.