Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature set
on the scale. To adjust please see page 36.
Operation thermostatic mixer bath tub
By turning the handle on the left hand side the ther-
mostatic mixer is opened, closed and the flow can
be changed from tub to shower function.
The temperature is selected by turning the graduated
handle on the right side.
Operation thermostatic mixer shower
The mixer is operated by turning the handle on the
left hand side. The green knob limits the rate of flow
to approx. 10 l/min. If a higher water consumtion
is required press the ECOSTOP button and turn
handle further.
The temperature is selected by turning the graduated
handle on the right side.

Temperature limitation

The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing
the safety button.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Attention!
The mixer is equipped with non return valves.
The non return valves must be checked regularly accor-
ding to DIN EN 1717 in accordance with national or
regional regulations (at least once a year)
1
English
Using the thermostatic mixer bath tub in
conjunction with combination boilers.
When using the Ecostat with combination boilers,
the Ecostop ring A has to be removed (please see
page 37).
If fitting a hand shower remove the water limiter
from the shower.
Using the thermostatic mixer shower in
conjunction with combination boilers.
If fitting a hand shower remove the water limiter
from the shower.
If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Anti-pollution function
max. 1 MPa
1,6 MPa
max. 80° C
65° C
18 l/min