Spare parts (see page 6/7)
1�
thermoelement
2�
shut off and diverter unit
3�
knob Ecostat E
4�
aerator cpl.
5�
non return valve
6�
noise reduction
7�
s-unions
8�
escutcheon Ecostat E
9�
safety set for temperature control 98916000
10�
nut
11�
safety set for flow control
12�
filter packing
13�
knob Ecostat S
14�
escutcheon Ecostat S
15�
nut
Fault
Insufficient water
Crossflow, hot water is forced into
cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not corre-
spond with the temperature set
Temperature regulation not possible - SMTC-thermo cartridge calcified - Exchange SMTC-thermo car-
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
English
98282000
98283000
98914000
96512000
96737000
96429000
94140000
94135000
98913000
95042000
96922000
98915000
96467000
96157000
Cause
- Supply pressure inadequate
- Filter are dirty (12)
- Shower filter seal dirty
- Backflow preventers dirty or
leaking
- Thermostat has not been ad-
justed
- Hot water temperature too low
- Dirt or sedaimentation on valve
seat, shut-off unit damaged
- Ecostop ring isn't removed
- Flow limiter in handshower isn't
removed
- Filter are dirty
- Non return valve didn't move
back
Remedy
- Check mains pressure
- Clean filter in front of the mixer
and on the SMTC-thermo car-
tridge (12)
- Clean filter seal between shower
and hose
- Clean backflow preventers,
exchange if necessary
- Adjust thermostat
- Increase hot water temperature
to 42 °C to 65 °C
- Clean or exchange shut-off unit
- Remove ecostop ring (A)
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves