to thermowell and mount it so that the part (6) is opposite to the ho-
le (1). Fit knob on body so that the pin (5) engages in hole (4). In
this case, the white mark has to point to the white figure „40" and
the red mark to the red figure „40". In this position, it is necessary
to press the knob against the spring as far as possible and to turn it
completely to the right, causing the mark to be aligned with figure
„30". Screw stud (3) into the knob. Insert connecting piece (9) with
hexagon screw (2) into hole (1). Make sure that the rectangular
recess (10) of the connecting piece (9) faces the hexagon of the
thermowell. Insert lever arm (11) and tighten hexagon screw (2).
Make sure that the hexagon screw bears on a flat surface of the le-
ver arm and does not press on an edge of the lever arm.
19