3.4 Lock/unlock
Allows all the settings to be locked from the control panel with
a security password.
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (551).
Activate the regulation of the selected parameter by pressing the
encoder button.
Set a numerical code (password) by rotating the encoder.
Confirm the change made by pressing the encoder button.
The carrying out of any operation on a locked control panel
causes a special screen to appear.
-
Access the panel functionalities temporarily (5 minutes) by
rotating the encoder and entering the correct password.
Confirm the change made by pressing button/encoder.
-
Unlock the control panel definitively by entering set-up (fol-
low the instructions given above) and bring back parameter
551 to "off".
Confirm the change made by pressing the encoder.
3.5 Motor calibration (set-up 707)
Allows you to calibrate the system.
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (707).
Press the encoder (1) to perform calibration (t1).
Use a measuring tape to measure the length of the wire deli-
vered.
Turn the encoder (2) entering the length in cm measured by the
measuring tape.
Press the encoder (1) to perform calibration (t2).
Use a measuring tape to measure the length of the wire deli-
vered.
Turn the encoder (2) entering the length in cm measured by the
measuring tape.
Press the encoder (1) to terminate the calibration procedure.

3.6 External controls management

Allows the setting of the welding parameters management
method by the external devices (RC, torch...).
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (602-603-604-605).
Select the required parameter (Min-Max) by pressing the
encoder button.
Adjust the required parameter (Min-Max) by rotating the
encoder.
Save and exit the current screen by pressing button/encoder.
3.7 Alarm codes
E01, E02
Temperature alarm
It is advisable not to switch off the equipment while
the alarm is on; the internal fan will thus keep
operating and will help to cool the overheated
parts.
E07
Wire feed motor supply alarm
E08
Blocked motor alarm
E10
Power module alarm
E13
Communication alarm (FP)
E18
Program not valid alarm
E19
System configuration alarm
E20
Memory fault alarm
E21
Data loss alarm
E40
System power supply alarm
E43
Coolant shortage alarm

3.8 Rear panel

1
Power supply cable
Connects the system to the mains.
2
Gas fitting (MIG/MAG)
3
Signal cable (CAN-BUS) input (RC) (optional)
4
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.