5 Functional description
5.2 Changing the filter
CAUTION
• Check and wear your personal protective equipment.
• The personal protective equipment consists of protective clothing, safety goggles, respirator mask class P3, protective
gloves and safety shoes.
• Nobody without personal protective equipment may stay near the dust collecting drawer when filling the separated
dust into it.
NOTICE
• A filter change must be carried out if, after multiple dedusting, a vacuum of >180 mbar is still reached, and no other
error or reason can be detected.
 Fig. 2 Functional Description on page EN-12
1 Loosen the fixation (1) and lift off the cover.
2 Remove the hose used for monitoring the manometer pressure (on the manometer).
3 Unscrew the two lock nuts (5) on the threaded bars of the corresponding filter.
4 Remove the fastener (4).
5 Remove the filter (3).
The filter is mounted in reverse order.
EN - 14