Herunterladen Diese Seite drucken

Dimplex LA 18I-MU Montage- Und Gebrauchsanweisung Seite 25

Vorschau ausblenden Andere Handbücher für LA 18I-MU:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LA 18I-MU
Type and order code
2
8
Heat output COP
8.1
Heat output / COP
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? to 60?.
2. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7 °C and heating water flow temperature 35 °C.
3. The heat output and COP is reduced by approx. 5 % in lower operation
4. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
5. See CE declaration of conformity
6. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
Performance level
at A-7 / W35
at A2 / W35
min
at A2 / W35
max
at A7 / W35
452168.66.09 · FD 9706
kW / ---
kW / ---
kW / ---
kW / ---
English
LA 18I-MU
EN 14511
9.4 / 2.9
5.9 / 3.7
7.9 / 3.6
5.7 / 4.6
EN-11

Werbung

loading