1 Operating Elements and Connections

1 Zoom buttons for modifying the focal length
"W": reduction of the focal length
The angle of view is wider; the object to be moni-
tored is zoomed out.
"T": extension of the focal length
The angle of view is reduced; the object to be moni-
tored is zoomed in.
With the OSD menu recalled, these buttons are used
to select the menu items.
2 Button for recalling and exiting the OSD menu pages
3 Focus buttons for manual focussing of the picture
"N":
focussing of objects nearby
"F":
focussing of objects far away
If the camera is set to autofocus, it is impossible to
focus the picture manually via the focus buttons.
With the OSD menu recalled, these buttons are used
to modify the menu settings.
4 Power LED
5 Button "AF / MF" (on the camera) or buttons "A / F" and
"M / F" (on the remote control RMA-1602) for a quick
change-over between the settings "manual focus" and
"autofocus",
after the button has been pressed, the screen will
shortly display the focus setting selected: "AF" or "MF"
6 3-pole tip jack for external control of zoom and focus
functions via a control unit; for configuration of the jack
see chapter 5.3
7 Switch "TERMINATION" for connecting the terminat-
ing resistor during remote control via RS-485 data
transmission
When controlling a single camera, set the switch to
"ON"; when controlling several cameras set the switch
on the last camera to "ON", the switch on the other
cameras to "OFF"
8 Connection "REMOTE" for remote control of the
camera
– via the optional remote control RMA-1602 or
– by RS-485 data transmission via a computer or
control console
9 Screw terminals "+12V" and "GND" for connecting the
power supply (12 V / 500 mA), the screw terminal
"F.G" of the terminal strip remains unconnected