2. Safety precautions

2.1 General safety precautions

Be sure to observe the following safety pre-
cautions when using the air dehider:
Installation, maintenance and repair work may
only be carried out when the machine is discon-
nected from the compressed air network!
For the operation it is assumed that the operat-
ing personnel is sufficiently familiar with the use
of the air dehider.
Instruction is provided by our specialist person-
nel.
Select personal protection equipment according
to the regulations applicable on the premises
and to the accident prevention regulations in
force.
Installation, maintenance and repair work may
only be carried out by authorised and qualified
personnel.
Air dehiders from Schmid & Wezel comply with
the relevant safety regulations.

2.2 Behaviour at the place of work

1. Keep your place of work tidy. Untidiness can
lead to accidents.
2. Give consideration to environmental influences.
Ensure good lighting (min. 500 lux).
3. Keep other people away from your place of
work. Work in a concentrated and sensible man-
ner. Do not use the air dehider when you are
unconcentrated and/or tired.
4. Store the air dehider in a safe place. Store the
air dehider in a dry place when not in use.
5. Work clothing: Do not wear loose clothing or
jewellery as these could become tangled up in
moving parts. Wear solid shoes when working.
Wear a hair net as a general rule!
6. Avoid abnormal body postures. Ensure a safe
working position and keep your balance at all
times.
7. Service your tools with care. Use only sharp and
undamaged strippers so that you can work bet-
ter and safer.
8. Use only original EFA strippers. Follow the
instructions given under "Changing the strip-
pers".
9. Do not leave wrenches on the machine. Check
that all wrenches have been removed before
Schmid & Wezel
D 75433 Maulbronn
starting the machine.
10.Use only original EFA accessories. Use of other
tools or accessories may result in injury to your-
self. Use of non-original accessories will void the
warranty.
11.Modifications and changes to the machine are
not permitted and will relieve S&W of any war-
ranty and liability.
3. Commissioning and opera-
tional safety
Place of work
The working area for the operator should be at
least 15 square feet. No other place of work should
extend into this area, as the movements with the
cutter could result in the risk of injury.
The illumination at the place of work must be at
least 500 lux.

3.1 Initial operation

Switch off the air dehider before
connecting to the works network!
Important information, e.g. technical
data sheets, drawings and parts lists
can be found in Annex A (p. 23).
3.1.1 Spring balancer
The machine is not operated in combination with a
weight relief system (spring balancer).
3.1.2 Air conditioner
The air dehider is operated with compressed air.
The connection must be made via an air conditioner
R3/8". The supply line for the connection of the ma-
chine must have an inside diameter of at least 3/4".
The air supply from the air conditioner must come
from above via the compressed air hose (inside di-
ameter min. 13 mm).
The air conditioner must be set to 2-3 drops of oil
per minute to ensure lubrication of the pneumatic
motor.