Power supply input Wiring Diagram

Power supply input at Indoor unit Terminal Block (Recommend)
Power supply
input
Power supply input at Outdoor unit Terminal Block (Optional)
INDOOR UNIT
OUTDOOR UNIT
CAUTION
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected ¿ rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to ¿ xed wiring : A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the ¿ xed wiring.
01_1118350101-1 EN.indd 10
Indoor
Terminal
Block
CHASSIS
CHASSIS
EARTH
Indoor
Terminal
Block
CHASSIS
Outdoor
Terminal
Block
CHASSIS
EARTH
10
INDOOR UNIT
OUTDOOR UNIT
Outdoor
Terminal
Block
Power supply
input