Herunterladen Inhalt Inhalt Diese Seite drucken

Message Codes - CONDTROL Vector 100 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Vector 100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LASER DISTANCE METER
EN
Timer
Short press
Enter menu of functions.
Short press
/
Select function "Timer"
Symbol
Short press
Short press
/
Set response time.
Start the timer.
As soon as response time runs out, measurement
Short press
will be taken.
Measurement result will appear in the main line.
Short press
Exit the mode.
Bluetooth
Short press
Enter menu of functions.
Short press
/
Select function "Bluetooth"
Switch on Bluetooth. Symbol
Short press
Symbol
screen.
tablet PC or laptop. For further operation use
application Smart Measure CONDTROL.
Switch off Bluetooth. Symbol
Short press
Symbol
from the display on the main screen.
22
Vector 100 CONDTROL
User manual
will appear on display.
Default value is 5 seconds.
turns blue.
appears on the display on the main
Activate Bluetooth in the smartphone,
turns grey.
will disappear
LASER DISTANCE METER
EN
Memory
Short press
Enter menu of functions.
Short press
/
Select function "Memory"
A number of the measurement/calculation result is
Short press
reflected in the symbol
Short press
/
Flip through saved measurement/calculation results.
Short press
Exit the mode.

MESSAGE CODES

While operation, the following codes/symbols may appear on the display:
Message
Cause
ERR 1
Laser signal is too weak.
ERR 2
Laser signal is too strong.
ERR 3
Low battery.
ERR 4
Failure of memory.
Failure of calculation by
ERR 5
Pythagoras Theorem.
Measuring result exceeds
ERR 6
permissible measuring
range.
ERR 7
Failure of tilt sensor.
Vector 100 CONDTROL
User manual
on the display.
Solution
Use a reflective plate.
Use a reflective plate.
Charge the battery.
Contact the service center.
Repeat the measurement.
Please change to longer distance
product.
Please contact service center.