Herunterladen Inhalt Inhalt Diese Seite drucken

Advantech DLT-V83 series Sicherheitshinweise Und Installationsanleitung Seite 26

Vorschau ausblenden Andere Handbücher für DLT-V83 series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6
NOTES ON THE ELECTRICAL INSTALLATION
Available power supply units
Integrated direct current (DC) power supply unit
Available for all device variants of the DLT-V83 series:
− Integrated, galvanically separated direct current power supply unit
− 12/24/48 VDC nominal (wide-range power supply unit)
− 60 W / 80 W internal, type DC-16
− Voltage range 9 to 60 VDC
NOTICE: Property damage
Fit fuses to the following supply lines:
− The DC+ connecting cable must be protected by a fuse (max. 30 AT).
− The ignition connecting cable must be protected by a fuse of the following type:
5x20 mm T 125 mA L / 250 V, for example Wickmann 195-125 mA / 250 V.
Integrated alternating current (AC power supply unit)
Only available for the DLT-V8315 device variant:
− Integrated, galvanically separated alternating current power supply unit, type AC-4
− Nominal voltage 100 to 240 VAC
− Voltage range 85 to 264 VAC
− Connection to the power supply on the underside of the device via an angled
connector for non-heating apparatus
WARNING
Danger of death due to hazardous voltage, electric shock.
− Do not open DLT-V83 devices with AC power supply unit while they are connected to
the power supply; doing so represents a danger to life.
− Before installing, observe the "DLT-V83 Operating Instructions", "AC devices" section.
22