5. Commissioning
Following proper installation and wiring, the
measuring system can be commissioned by
switching on the supply voltage. After switching
on, the device initializes itself independently.
When the sensor is moved along the magnetic
tape, LEDs are activated as follows:
LED Color Function
A
green Power
B
red
Active if cos < /cos
C
red
Active if sin < /sin
D
red
Active if /ref < ref
A B C D
8
LE200+MB200
Signal
sin
cos
index
+UB
GND
viewing side =
/sin
plug-in side
/cos
/index
Datum 09.11.2009

6. Maintenance

We recommend cleaning the magnetic strip's sur-
face from time to time with a soft rag. This avo-
ids dirt (dust, chips, humidity ...) sticking to the
strip.
7. Trouble shooting
Below are some typical errors which may occur du-
ring installation and operation:
Magnetic strip incorrectly mounted (active sur-
face must be mounted towards the sensor) (see
chapter 3.1).
Sensor incorrectly connected.
Tolerance for the gap between magnetic sensor and
magnetic strip not observed over the total travel
distance. Sensor touches strip (see fig. 7).
Cable squeezed / interrupted / cut by sharp
edges.
Sensor's active side not mounted towards the
magnetic strip (see fig. 7).
Sensor has not been aligned according to fig.
6+7.
SIKO GmbH
Werk / Factory:
Weihermattenweg 2
79256 Buchenbach-Unteribental
Postanschrift / Postal address:
Postfach 1106
79195 Kirchzarten
Telefon/Phone
+49 7661 394-0
Telefax/Fax
+49 7661 394-388
E-Mail
info@siko.de
Internet
www.siko.de
Service
support@siko.de
Art.Nr. 84882
Änd. Stand 326/09

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mb200

Inhaltsverzeichnis