Herunterladen Inhalt Inhalt Diese Seite drucken

Dual-Trace Operation - PeakTech 2035 Bedienungsanleitung

30 mhz analog-oszilloskop
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.
To set X5 MAG switch at x5 in case motif is not made or difficult to measure as the sign to be
measured is too small despite VOLT/DIV, switch was placed at 5 mV.
In this instance if VOLT/DIV. switch ist 5 mV, become to 1 mV/DIV and frequency oscillation
reduces to 10 MHz and noise will be increased by the revolution.
6.
To set X10 MAG switch at X 10 MAG (11) when too many cycles appear on even the TIME/DIV
switch was put on 0.2 µs position as the sign try to be measured is a high frequency.
Then, it will be 0.2 µs 20 ns/DIV because of sweep width increases by 10 times and in case of 0.5
µs it will be 50 ns/Div.
7.
If the signal you wish to observe is either DC or low enough in frequency that AC coupling
attenuates of distorts the signal, flip the AC/GND/DC switch (25) or (21) to DC.
Caution: If the observed waveform is low-level AC, make certain it is not riding on a high-
amplitude DC voltage.
You will also have to reset the Trigger MODE switch (14) to NORM if the signal frequency is
below 25 Hz, and possibly readjust the Trigger LEVEL control (9).
2.2.4

Dual-trace operation

Dual-trace operation is the major operating mode of the unit. The setup for dual-trace operation is
identical to that of 2.3.2 Single-trace operation with the following exceptions:
1.
Set the V MODE switch (5) to either DUAL. Select ALT for relatively high frequency signals (A
TIME/DIV switch set to 0.5 ms or faster). Select CHOP for relatively low-frequency signals
(TIME/DIV switch set to 1 ms or slower).
2.
If both channels are displaying signals of the same frequency, set the Trigger SOURCE switch
(18) to the channel having the steppest-slope waveform. If the signals are different but
harmonically related, trigger
that if you disconnect the channel serving as the trigger source, the entire display will free run.
from the channel carrying the lowest frequency. Also, remember
(a) Composite Video Signal