Herunterladen Inhalt Inhalt Diese Seite drucken

Features Of Transmission Modules - G&D DP1.2-Vision-Fiber Installation Und Bedienung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Features of transmission modules

MULTIMODE TRANSMISSION MODULE
Data transmission
Cable length (max.)
Performance data
SINGLEMODE (S) TRANSMISSION MODULE
Data transmission
Cable length (max.)
Performance data
SINGLEMODE (S+) TRANSMISSION MODULE
Data transmission
Cable length (max.)
Performance data
Type:
Type of interface:
Multimode 62.5/125 μm:
Multimode 50.0/125 μm,
Class OM2:
Multimode 50.0/125 μm,
Class OM3:
Wavelength(λ):
Optical power output (P
OUT
in 50 oder 62,5 μm MMF:
Receiving sensitivity (P
MIN
Sensitivity – Stressed (P
):
S
Type:
Type of interface:
Singlemode 9/125μm,
Class OS1:
Wavelength(λ):
Optical power output (P
OUT
in 9 μm SMF:
Receiving sensitivity (P
MIN
Type:
Type of interface:
Singlemode 9/125μm,
Class OS1:
Wavelength(λ):
Optical power output (P
OUT
in 9 μm SMF:
Receiving sensitivity (P
MIN
Optical fibres (2 fibres)
LC duplex
100 meters
200 meters
400 meters
850 nm (830 nm bis 860 nm)
)
-9,0 dBm bis -2,5 dBm
):
-15 dBm (OMA)
138μW (50 μm MMF)
Optical fibres (2 fibres)
LC duplex
5 Kilometer
1310 nm (1260 nm bis 1350 nm)
)
-9,5 dBm bis -3,0 dBm
):
-18 dBm (OMA)
Optical fibres (2 fibres)
LC duplex
10 Kilometer
1310 nm (1260 nm bis 1360 nm)
)
-8,4 dBm bis -1,0 dBm
):
-18 dBm (OMA)
G&D DP1.2-Vision-Fiber · 68