Troubleshooting
ERROR type fault messages
All faults of the ERROR type must be reset manually:
➤ RMD10.5T, RMD10.5XT: Press the control knob for 2 seconds.
➤ RMD10.5, RMD10.5X: Press
✓ A beep sounds.
✓ The error has been reset.
RMD10.5T,
RMD10.5,
RMD10.5XT
RMD10.5X
E03
E07
E08
E09
E12
E13
E14
26
for 2 seconds.
Fault
No connection between
power module and display
No cooling capacity in gas
mode
No cooling power in AC
mode
No cooling power in DC
mode
Gas valve check error
Internal communication error Gas operation not possible.
In stand-alone gas mode:
The battery charge of the
battery packs is too low
Solution
Contact an authorized customer
service.
Check if the device is at an angle
and adjust it if necessary.
Reset the error.
Contact customer service if this
error occurs again.
Check if the device is at an angle
and adjust it if necessary.
Reset the error.
Contact customer service if this
error occurs again.
Check if the device is at an angle
and adjust it if necessary.
Reset the error.
Contact customer service if this
error occurs again.
Gas operation is not possible.
Reset the error.
Contact customer service if this
error occurs again.
Reset the error.
Contact customer service if this
error occurs again.
Insert new batteries and then reset