REPLACING OIL
The hydraulic system is a closed system with
oil tank, oil pump and control valve. Low oil
levels can damage the oil pump. Check oil
level regularly with dipstick. The oil should
be completely changed once a year.
Following hydraulic oils or equivalent are
recommend for the log splitter's hydraulic
transmission system:
SHELL Tellus 22
MOBIL DTE 11
ARAL Vitam GF 22
BP Energol HLP-HM 22
Make sure moving parts stop and the log
splitter is unplugged and PTO driveshaft is
disconnected. Use a drain pan to aid in the
removal of all used oil and particles. Remove
oil drain plug to drain oil from the hydraulic
transmission system. Examine oil for metal
chips as a precaution to future problems.
After oil has been completely drained from
Hydraulische Holzspalter / Hydraulic log splitters ZI-HS13E/ZI-HS18EZ/ZI-HS25Z / ZI-HS25EZ
the machine, reinstall drain plug. Add the
hydraulic transmission system with recom-
mended oil through filler plug opening.
Read dipstick to determine the
maximum and minimum of the
oil level. Low oil can damage
the oil pump. Overfilling can
result in excessive tempera-
ture in the hydraulic transmis-
sion system.
Apply sealant to filler plug and reinstall it.
Following an oil change, activate the log
splitter a few times without actually splitting.
SHARPENING WEDGE
This log splitter is equipped with reinforced
splitting wedge which blade is specially
treated. After long periods of operation, and
when required, sharpen the wedge using a
fine-toothed file removing any burrs or flat
spots on the edge.