Mounting the control panel

Please observe the following instructions for the installation location:
 Observe the length of the extension cable from the control panel to the
generator.
➤ Drill the holes as shown in fig. 0, page 6.
➤ Insert the plug into the control panel.
➤ Screw on the control panel.
10
Connecting the electrical power to the
generator
D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
I
NOTE
Observe the applicable guidelines in the country of the consumer.
10.1
Important notes on the electrical connection
 Only a qualified electrician should connect the generator to the electrical
power.
 Check that the voltage specification on the type plate is the same as that
of the power supply.
 Do not lay the 230 Vw mains cable and the 12 Vg cable together in the
same cable duct.
 Do not lay cables which are loose or bent next to electrically conductive
material (metal).
 Connect the generator to a power circuit which can supply the necessary
current (see chapter "Technical data" on page 24).
 Select the cross-section of the cable as follows:
– 230 V: 4 mm²
– Battery charger: 2.5 mm²
– Starter battery connection (length < 6 m): 16 mm²
– Starter battery connection (length > 6 m): 25 mm²