INSTALLATION

Installation
8.1.2 ESH 10 O-P Plus - oversink installation
Note
The appliance is only suitable for oversink installation.
The water connections of the appliance point downwards.
9.
Installation
Material losses
!
When using plastic pipework observe the extreme oper-
ating and fault conditions that can occur on the appliance
(see chapter "Installation / Specification / Extreme oper-
ating and fault conditions").
f Run the connections to the second tap on site, e.g. in 10 mm
f
copper pipe.
ESH 10 U-P Plus
f To supply two washbasins, use water distribution tees.
f
9.1

Installing the safety assembly

f Fit the diaphragm safety valve in the cold water supply line of
f
the appliance.
f Observe the information on the safety valve (see chapter "In-
f
stallation / Safety / Information on the safety valve").
f Observe the information in the installation instructions of the
f
safety valve.
f Fit a pressure reducer upstream of the diaphragm safety
f
valve in the cold water supply line if the supply pressure ex-
ceeds 0.48 MPa.
9.2

Appliance installation

f Mark out the holes to be drilled on the wall (see chapter "In-
f
stallation / Specification / Dimensions and connections").
f Drill the holes and insert suitable rawl plugs.
f
f Secure the wall mounting bracket using suitable screws.
f
f Hang the appliance on the wall mounting bracket.
f
Note
Surplus cable can be stored in the cable compartment.
16
| ESH 10 U-P Plus | ESH 10 O-P Plus
9.3

Water connection

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
Material losses
!
The appliance may lose its function.
f Never interchange the water connections.
f
f Set the flow rate (see safety valve instructions).
f
Observe the maximum permissible flow rate with a
fully opened tap (see chapter "Installation / Specifi-
cation / Data table").
Match up the colour coding on the tap water connections and the
appliance:
- R.h. side blue = "Cold water inlet"
- L.h. side red = "DHW outlet"
f Secure the water connections from the tap to the appliance.
f
Note
Ensure that the water connections are not kinked during
installation. Prevent any tensioning during installation.
9.4

Electrical connection

WARNING ELECTROCUTION
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING ELECTROCUTION
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
WARNING ELECTROCUTION
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.