3.5
Alarm (self-latching)
NOTICE
i
i
The alarm settings on the X-zone 5000 can be
configured using the Dräger CC-Vision PC software.
See the Instructions for Use for the Dräger X-zone
5000 for further information.
X-zone Switch Off:
When the connected X-zone 5000 generates an alarm,
the outgoing power supply is automatically interrupted by
the X-zone Switch Off.
X-zone Switch On:
When the connected X-zone 5000 generates an alarm,
the outgoing power supply is automatically switched on by
the X-zone Switch On.
3.6

Start-up after an alarm

NOTICE
i
i
The connected X-zone 5000 must no longer be in
the alarm state.
X-zone Switch Off
Press the emergency off switch (2) and unlock it with
the key (3).
The outgoing power supply is switched on and the power
supply LED lights green.
X-zone Switch On
Press the reset button (11).
The outgoing power supply is switched off and the power
supply LED goes out.
4
Troubleshooting
Faults
Cause
Input voltage not
Connecting cable
present
damaged
X-zone Switch Off/
The configuration
On is not switching
of the X-
zone 5000 is not
passing alarms on
Switch relay cable
or connecting
cable damaged
10
5
5.1
Observe EN 60079-17 and the relevant national laws and
regulations.
Before starting operation:
5.2
6
Disposing of electric and electronic equipment:
Special
established for households. However, as this device has not
been registered for household usage, it must not be disposed
of through these means. The device can be returned to your
national Dräger Sales Organisation for disposal. Please do not
hesitate to contact the above if you have any further questions
on this issue.
Remedy
Contact
DrägerService
Change the
configuration of
the X-zone 5000
using the Dräger CC-
Vision PC software
(see Instructions for
Use for the Dräger X-
zone 5000)
Contact
DrägerService
Maintenance
Maintenance intervals
Check cables are securely attached.
Check housing for visible damage.
Check sockets for contamination.
Check surface of plug pins for damage.
Cleaning
CAUTION
!
Never use abrasive or alcohol-containing cleaning
agents or solvents. Avoid ingress of water or cleaning
agents into the contact sockets.
Clean with a cloth, brush, vacuum cleaner or similar.
For moist cleaning, use water or a mild, non-scouring, non-
scratching cleaning agent.
Disposal
EC-wide regulations for the disposal of electric and
electronic appliances which have been defined in the
EC Directive 2002/96/EC and in national laws have
been effective since August 2005 and apply to this
instrument.
collecting
and
recycling
facilities
have
been
Dräger X-zone Switch Off/On

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

X-zone switch on

Inhaltsverzeichnis