Use
19. If the air supply unit is being used, connect the air supply to
the air supply unit.
20. Fit the overgloves if required:
a. Pull the K-MEX-Gigant overglove over the arm ring and
secure it with the corresponding rubber ring.
b. Pull the Tricotril overglove over the arm ring and secure
it with the corresponding rubber ring.
21. Put on the safety helmet where applicable.
NOTICE
i
i
In chemical protective suits with face cuffs the leak test
as described in steps 11 to 13 should not be regarded
as a reliable indication that the suit will fulfil its function
in the same way when worn by somebody else. For
maximum protection Dräger recommends checking
the fit individually for each wearer.
4.4

Observe during use

CAUTION
!
A heat build-up in the chemical protective suit can
result in circulatory collapse; for this reason, wear a
cooling vest underneath or use a suitable ventilation
system, as appropriate.
Never start a mission alone!
Observe the operating time, limitations and specific
national regulations. The maximum operating time may
also depend on the used respiratory protective device and
the operating conditions.
If you are working with refrigerated media, use the relevant
overgloves (e. g.Cryo-Industrial Gloves from Tempshield,
Inc.) and underclothing.
Leave the contaminated area immediately in a case of
emergency. Open fastener system in clean area only.
4.5

After use

4.5.1
Precleaning of the chemical protective suit
WARNING
!
Never touch contaminated parts unless wearing
protective clothing. Avoid contaminating the clean
interior of the suit.
Failure to meet the required safety precautions may
result in death or serious injury.
1. Leave the contaminated area and have the chemical
protective suit precleaned by an assistant. The assistant
must also wear protective clothing and breathing apparatus
where necessary.
For precleaning, Dräger recommends using plenty of water
to which a detergent has been added. This will be sufficient
to wash away most chemicals (acids, alkalis, organic and
inorganic substances).
1
not part of the EU type approval test
28
1
CAUTION
!
If precleaning is not possible on site, remove and close
the suit immediately to prevent chemicals from
entering the suit.
2. Clean the chemical protective suit thoroughly for a
sufficient time. Avoid spreading chemicals.
3. In the event of contamination with hazardous substances,
dispose of the waste water in line with the relevant waste
waster disposal regulations.
4. If necessary, carry out decontamination in several steps.
Further information on decontamination
from Dräger.
4.5.2
Taking off the chemical protective suit
WARNING
!
Only take off the chemical protective suit in a non-
contaminated area.
1. Remove the safety helmet where applicable.
2. If the chemical protective suit is equipped with an air supply
unit, have the air supply disconnected by a second person.
3. Disconnect the breathing apparatus from the full face
mask, and set down.
CAUTION
!
For chemical protective suits with face cuffs: if liquid
splashes or aerosols sprays occur that could have
penetrated between the full face mask and face cuff,
bend the head forward, remove the full face mask and
wipe down the face cuff without any chemicals getting
into the face area in the process.
4. Unfasten the straps on the full face mask:
Insert a finger underneath the straps on the neckband and
push the adjusting buckles forwards using your thumb.
5. If the chemical protective suit is equipped with an
integrated full face mask:
a. Open the cover strap.
b. Open the fastener system.
Always pull in the direction of the zip. Do not use force.
c. Remove the hood and mask back over the head.
d. After this point, take out the right arm, then the left arm
from the sleeves.
6. If the chemical protective suit is equipped with a face cuff:
a. Remove the full face mask.
b. Open the cover strap.
c. Open the fastener system.
Always pull in the direction of the zip. Do not use force.
d. Take your head out of the head part.
e. After this point, take out the right arm, then the left arm
from the sleeves.
7. If the chemical protective suit is fitted with braces, remove
the braces.
2