Note! This product is obsolete. For replacement see Sentry safety relays.

Safety Relay

Operating Instructions
Read and understand these instructions before installing,
operating, or maintaining the equipment.
DANGER
!
Hazardous voltage.
Will cause death or serious injury.
Turn off and lock out all power supplying this device before
working on this device.
CAUTION
Reliable functioning of the equipment is only ensured with
certified components.
The safety switching device must be installed in switchgear cubicles com-
plying with degree of protection IP32, IP43 or IP54, depending on the pre-
vailing environmental conditions.
IMPORTANT NOTICE
The products described herein are designed to be components of a customized
machinery safety-oriented control system. A complete safety-oriented system
may include safety sensors, evaluators, actuators and signaling components. It
is the responsibility of each company to conduct its own evalution of the effec-
tiveness of the safety system by trained individuals. ABB AG, its subsidiaries
and affiliates (collectively "ABB") are not in a position to evaluate all of the cha-
racteristics of a given system or product or machine not designed by ABB.
ABB accepts no liability for any recommendation that may be implied or stated
herein. The warranty contained in the contract of sale by ABB is the sole war-
ranty of ABB. Any statements contained herein do not create new warranties or
modify existing ones.
Application
The C6700 safety relay can be used in EMERGENCY STOP devices according to
DIN EN / IEC 60947-5-5 and in safety circuits according to DIN EN / IEC 60204-1,
e.g. for moving covers and protective doors. Max. Performance Level PL d / Cat. 3
according to DIN EN ISO 13849-1 or SIL 2 according to DIN EN / IEC 62061 can be
achieved, depending on the external circuit elements. The user must carry out an
evaluation of the overall systems.
Functional description and instructions for connection
The C6700 safety relay has two solid-state outputs. Three LEDs indicate the
operating state and the function.
During operation, all internal circuit elements are cyclically monitored for faults.
Connect the EMERGENCY STOP button and the position switch to terminals
Y11, Y12 or Y21, Y22. Connect the ON button in series with the NC contacts of
the external actuators (feedback circuit) to terminals Y33, Y34 .
The C6700 safety relay and the activated contactors K1 and K2 must have the
same frame potential.
Performance Level PL d according to DIN EN ISO 13849-1 and / or SIL 2 accor-
ding to DIN EN / IEC 62061 can only be achieved in combination with 2 external
actuators with positively-driven feedback contacts.
Use a power pack to IEC 60536 safety class III (SELV or PELV)
for power supply!
Terminal
Operating
A1
voltage
A2
assignments
Sensors Y11, Y12
Y21, Y22
Y20
Y33, Y34
Outputs
14, 24
2
Cable lengths for 2 x 1.5 mm
2
L+
M
Channel 1 EMERGENCY STOP or
position switch
Channel 2 EMERGENCY STOP or
position switch
Changeover contact, single-channel
ON button, feedback circuit
Solid-state outputs
max. 2000 m (total cable length for sensors)
Order No.: 2CDC 113 023 M9701
Figures Fig. I:
Dimension drawings (dimensions in mm)
Fig. Ia:
Terminal designation
Fig. II:
Installation/Connection
Fig. IIIa: Safety data
Fig. IIIb: Application data
Fig. IV:
Internal circuit: ¿ power pack, À control logic,
Á Output 1, Â Output 2
Fig. V:
Two-channel autostart for protective door monitoring,
Fig. VI: EMERGENCY STOP, two-channel, with monitored start
Fig. VII: EMERGENCY STOP, single-channel, with monitored start
Fig. VIII: Single-channel autostart for protective door monitoring,
category 2/SIL1*
Operating states
LEDs
Operation
POWER RUN
FAULT
PS
ON
Faults
• Defect in electronics
• Crossover in EMERGENCY STOP
circuit
No supply voltage
Technical data
Permissible ambient temperature T
u
Operation / storage
Degree of protection to DIN EN / IEC 60529
Rated insulation voltage U
i
Rated impulse withstand voltage U
imp
Rated control supply voltage U
s
Rated power
Operating range
Shock resistance (half-sine) as per
DIN EN / IEC 60068
Weight
Recovery time after EMERGENCY STOP
Release time after EMERGENCY STOP
Pickup time, monitored start
Pickup time, autostart
Release time after power failure
Short-circuit protection
Utilization category
Rated operational
voltage U
as per
e
(V)
DIN EN / IEC 60947-5-1
DC-13
24
For further data and accessories see Catalog.
C6700
DIN EN / IEC 60947-5-1
English
EMERGENCY
ON
Outputs
STOP
not
on
was activated
activated
activated
not
off
activated
not
not
off
activated
activated
off
–25 to +60 °C / –40 to +80 °C
IP40, IP20 at terminals
50 V
500 V
24 V DC
1.5 W
0.9 to 1.15 x U
s
8 g / 10 ms
150 g
min. 20 ms
< 30 ms
< 125 ms
< 250 ms
< 25 ms
no fusing necessary!
Rated operational current I
per output (A)
60 °C
0.5
e

Werbung