If the sensor is in the adjustment mode, the enable zone of the sensor
can be determined by moving the damping element.
enable zone
Signal
Power
Explanation of symbols:
LED out
32
Signal
Signal
Power
Power
LED on
As soon as damping is done
in the enable zone, the yellow
signal LED goes out.
If the damping element is in
the close zone or directly
around the enable zone, the
signal LED starts to flash
again.
If the sensor is undamped for
over 2 s (> 30 mm), the
adjustment mode is switched
off and the yellow signal LED
goes out.
This can also be achieved by
interrupting the voltage.