12.Place back the cover of junction box and lock it.
Cupboard fans can be controlled with a cooker hood now.
8.2.1.1 Fan speed configuration
It is possible to adjust the minimum and normal fan speed
by internal potentiometers located next to the lamp. Max-
imum speed is not adjustable and always 10 V.
The potentiometers are adjusted by means of a screw
driver.
Turning the potentiometer results in different control vol-
tages to the fans. To get an idea of the airflow corre-
sponding to each voltage output see 3.2.3 Performance.
Fan performance diagrams show performance curves for
extract air.
Speed setting
Minimum speed (1)
Normal speed (2)
Maximum speed (3)
8.2.2
392–14 Slimline EC
This product will be available in the 4th quarter of 2018.
The cooker hood is internally wired and equipped with a cable for a control signal to the ventilation unit (0-10 VDC) and
power cable.
Component/product — Article number:
• 392-14 EC Slimline White — 96805
Installation and connection
1. Remove the cover of junction box (pos. 1) by turning four locks in each corner from position 1 to 0.
2. Pull out potentiometer connected to sockets 2, 3 and 4 on the terminal block.
3. Connect 230 V~ neutral (N) wire to the N socket on the terminal block (blue wire).
4. Connect 230 V~ phase (L) wire to the L socket on the terminal block (brown wire).
211877 | A006
Voltage range
1,5-5 V
2-8 V
10 V (not possible to
change)
Fig. 9 392–14 Slimline EC connection
Fig. 1 H1 — minimum speed voltage, H2 — normal
speed voltage
Accessories |