Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco CombiCool CAS-60 Einbau- Und Bedienungsanleitung Seite 42

Absorber-kühlschrank
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
CAS-60.book Seite 42 Dienstag, 10. Oktober 2006 3:41 15
Connecting the refrigerator
Connecting the refrigerator to an outside supply
Note!
Only use the WAECO hose with quick coupling (optional accesso-
ry).
➤ Note the norms EN 732 and EN 1949.
➤ Make sure the pressure is limited to 30 mbar.
➤ Connect one end of the hose to the port (fig. 4 1, page 5) on the refrig-
erator by turning the union nut anticlockwise.
Use an open-end spanner (17 mm) to turn the nut and a 13 mm spanner
to hold it.
➤ Take the cap off the coupling (fig. 4 2, page 5).
➤ Push the sleeve into the coupling (fig. 4 2, page 5) until you hear it
catch.
➤ Open the valve on the coupling (fig. 4 2, page 5).
➤ Open the gas tank valve.
➤ Check all connections with leak spray.
There are no leaks if no bubbles form.
➤ Put the refrigerator into operation (chapter „Putting the refrigerator into
operation" on page 44).
To disconnect the gas:
➤ Close the valve on the coupling (fig. 4 2, page 5).
➤ Disconnect the gas hose.
To do this, push the sleeve towards the handle with the valve closed.
➤ Put the cap on the coupling (fig. 4 2, page 5).
42