CombiCool CAS-60
7.3
Connecting to a gas source
Caution!
Note the following instructions when operating the appliance with
gas:
– It may not be installed for gas operation in road vehicles and
water vessels.
– It may not be operated with liquid gas in closed rooms.
– It should be installed in a room of at least 20 m³ in volume, with
windows or a door to the open air.
Caution!
Only use cylinders of propane or butane gas (not natural gas) with
an approved pressure reduction valve and suitable top part.
Caution!
Two different versions are available:
– For a supply pressure of 30 mbar
– For a supply pressure of 50 mbar
Always operate the appliance at the pressure shown on the type
plate.
Please note the pressures which are permitted in your country.
Use a DIN-DVGW-approved pressure regulator with a fixed setting
in accordance with DIN EN 12864. In Germany, it must supply a
gas pressure of 50 mbar.
Caution!
The connection must be replaced in accordance with national
guidelines.
There are two ways to connect the refrigerator. Note the connections and
permissible pressures listed in the table:
Connection location Connection
Outside connection
Gas cylinder
Hose with quick coupling
(available as accessory)
Hose with screw connector
Connecting the refrigerator
Permissible pressure
30 mbar
DE: 50 mbar
AT: 50 mbar
DK, FI, NL, NO, SE: 30 mbar
BE, ES, FR, GB, IE, IT, PT:
28 – 30/37 mbar
41