IG06, IG07
Commissioning
• E9 (IG06): 5 pole socket contact (Fa. WAGO)
Assignment IG06: output circuit PP
PIN
1
2
3
4
5
5 Commissioning
Please carefully read the information on the encoder's mechanical and
electrical connection. This will ensure a trouble free commissioning and
operation.
Before operation, please check again:
• that the supply voltage's polarity is correct.
• correct connection of cable and signal lines.
• secure encoder fixation.
The encoder's and follower electronic's (e. g. con simultaneoulsy to avoid
latch-up effects on the encoder's outputs.
` Now the encoder can be used.
6 Output circuits
PP (Push-Pull); IG06
PP, PN (Push-Pull); IG07
Fig. 4: Output circuit PP, PN
IG06, IG07 · Date 08.03.2019 · Art. No. 79650 · Mod. status 33/19
Signal
+UB
channel B
channel A
X
GND (screening)
viewing side =
plug-in side
socket contact
English
31