8.3,
FIRST STARTING.
W ARNING: The first machine starting operations must be carried out by a specialised and authorised technician.
Open the water supply tap upstream of the machine.
Turn the switch (1) to position "
Press the button "
display (3):
The LED (4a) on all the machine pushbutton panels will come on.
The boiler will automatically start to fill with water.
W ARNING: If filling does not start within 120 seconds, the machine goes into alarm and the LEDs positioned on the
pushbutton panels of the units will come on flashing.
Turn the machine on and off again to complete filling the boiler with water.
Press the continuous dispensing button "
"
" (5) again to stop dispensing.
Turn the switch (1) to position "
When the set temperature has been reached, the LED (6) will go off and the pressure in the boiler will be 1.2-1.3 bar (0.12-0.13
MPa) indicated on the pressure gauge (7).
Dispense a few times from the units, water tap and steam nozzles checking proper functioning (see the paragraph on operation
for how to operate).
22
"; the LED (2) will come on and the following will be shown on the display (3) (OFF status).
" (4) on the left-hand pushbutton panel to change from OFF to ON; the following will be shown on the
VIBIEMME
" (5) and wait until water without air bubbles comes out, then press the button
"; the LED (6) will come on indicating that the boiler heating element is on.