-1
No load speed (min
)
Dimensions (L x W x H)
Net weight
Safety class
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
Read instruction manual.

DOUBLE INSULATION

To avoid injury from flying debris, keep
holding the saw head down, after
making cuts, until the blade has come to
a complete stop.
Do not place hand or fingers close to the
blade.
For your safety, remove the chips, small
pieces, etc. from the table top before
operation.
Always set SUB-FENCE to left position
when performing left bevel cuts. Failure
to do so may cause serious injury to
operator.
To loosen the bolt, turn it clockwise.
Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible recycling
facility.
Intended use
The tool is intended for accurate straight and miter
cutting in wood. With appropriate saw blades, aluminum
can also be sawed.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated and can, therefore, also be used from
sockets without earth wire.
END217-3
equipment
and
ENE004-1
ENF002-2
For Model LS1040
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.29 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
Noise
The typical A-weighted noise level determined according
to EN61029:
Sound pressure level (L
Sound power level (L
Uncertainty (K) : 3 dB(A)
Vibration
The vibration total value (tri-axial vector sum) determined
according to EN61029:
Vibration emission (a
Uncertainty (K) : 1.5 m/s
its
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
The vibration emission during actual use of the
power tool can differ from the declared emission
value depending on the ways in which the tool is
used.
Be sure to identify safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it
is running idle in addition to the trigger time).
6
530 mm x 476 mm x 532 mm
) : 91 dB(A)
pA
) : 101 dB(A)
WA
Wear ear protection
2
) : 2.5 m/s
or less
h
2
4,600
12.4 kg
/II
ENF100-1
ENG905-1
ENG900-1
ENG901-1