About the device
Mains input
Input voltage range
Input voltage range optional
Required phases
Input frequency
Input fuse
Input current
Power factor
Output - Voltage
Nominal voltage U
Nom
Adjustable range
Stability at mains fluctuation ±10% ∆U
Stability at 0...100% load
Ramp-up time 10...90% at 100% load
Ripple @ BWL 20MHz
Accuracy*
Resolution of display
Remote sense compensation
Overvoltage protection
threshold (adjustable)
Output - Current
Nominal current I
Nom
Adjustable range
Stability at mains fluctuation ±10% ∆U
Stability at 0...100% ∆U
OUT
Ripple @ BWL 20MHz
Accuracy*
Resolution of display
Transient recovery time 10....90% load
Output - Power
Nominal power P
Nom
Nominal power at derating
Accuracy*
Resolution of display
Efficiency
Miscellaneous
Ambient temperature
Storage temperature
Humidity rel.
Dimensions (WxHxD) **
Weight
Redundancy
Isolation output to enclosure
Isolation input to output
Cooling
Standards
Overvoltage class
Protection class
Pollution degree
Operational altitude
Series operation
max. series connection voltage
Master-Slave
Parallel operation
max. parallel connection voltage
Master-Slave
Analogue programming
Input range
Accuracy
Input impedance
Article number
* Related to the nominal value, the accuracy defines the maximum allowed deviation between set value and actual value.
Example: a 80V model has min. 0.2% voltage accuracy. This is 160mV. When setting a voltage of 5V and with an allowed maximum deviation of 160mV, the resulting
actual value could be between 4.84V and 5.16V.
Instruction Manual
PS 8000 3U Series
PS 8040-510 3U PS 8080-340 3U PS 8160-170 3U PS 8200-140 3U
340...460V
340...460V
588...796V+MP
L1, L2, L3, PE
L1, L2, L3, PE
50/60Hz
50/60Hz
6x T16A
4x T16A
max. 19A
max. 28A
> 0.99
40V
0V...U
0V...U
Nom
< 0.02%
< 0.02%
IN
< 0.05%
< 0.05%
max. 30ms
max. 30ms
< 150mVpp
< 150mVpp
< 10mVrms
< 10mVrms
≤ 0.2%
10mV
max. 2.5V
max. 2.5V
0...44V
0....88V
510A
0...I
0...I
Nom
< 0.05%
< 0.05%
IN
< 0.15%
< 0.15%
< 900mApp
< 600mApp
< 120mArms
< 80mArms
≤ 0.2%
100mA
100mA
< 2ms
10000W
10000W
0...P
0...P
Nom
≤ 0.2%
0.01kW
0.01kW
93%
0....50°C
0....50°C
-20....70°C
-20....70°C
< 80%
19" 3U 595mm
19" 3U 595mm
33kg
yes
500V DC
500V DC
by fans, air inlet on the front, air exhaust on the rear
09230178
09230161
340...460V
-
-
L1, L2, L3, PE
50/60Hz
4x T16A
max. 28A
> 0.99
> 0.99
80V
160V
0V...U
Nom
Nom
< 0.02%
< 0.05%
max. 30ms
< 300mVpp
< 30mVrms
≤ 0.2%
≤ 0.2%
10mV
100mV
max. 5V
0....176V
340A
170A
0...I
Nom
Nom
< 0.05%
< 0.15%
< 300mApp
< 60mArms
≤ 0.2%
≤ 0.2%
10mA
< 2ms
< 2ms
10000W
0...P
Nom
Nom
≤ 0.2%
≤ 0.2%
0.01kW
93%
93%
0....50°C
-20....70°C
< 80%
< 80%
19" 3U 595mm
25.5kg
25.5kg
yes
no
500V DC
4200V DC
EN 60950, EN 61326, EN 55022 Class B
2
1
2
<2000m
600V
no
1500V
yes, via Share bus
0...5V or 0...10V, selectable
≤ 0.2%
53kOhm
09230163
Date: 06-27-2011
EN
PS 8400-70 3U
340...460V
340...460V
-
-
L1, L2, L3, PE
L1, L2, L3, PE
50/60Hz
50/60Hz
4x T16A
4x T16A
max. 28A
max. 28A
> 0.99
> 0.99
200V
400V
0V...U
0V...U
Nom
Nom
< 0.02%
< 0.02%
< 0.05%
< 0.05%
max. 30ms
max. 30ms
< 200mVpp
< 300mVpp
< 25mVrms
< 40mVrms
≤ 0.2%
≤ 0.2%
100mV
100mV
max. 6V
max. 12V
0...220V
0...440V
140A
70A
0...I
0...I
Nom
Nom
< 0.05%
< 0.05%
< 0.15%
< 0.15%
< 89mApp
< 33mApp
< 22mArms
< 9mArms
≤ 0.2%
≤ 0.2%
100mA
10mA
< 2ms
< 2ms
10000W
10000W
0...P
0...P
Nom
Nom
≤ 0.2%
≤ 0.2%
0.01kW
0.01kW
95.20%
95.20%
0....50°C
0....50°C
-20....70°C
-20....70°C
< 80%
< 80%
19" 3U 595mm
19" 3U 595mm
25.5kg
25.5kg
yes
no
500V DC
900V DC
09230171
09230173