MSH Basic-FUBO-E-SR4 / MSH Basic-MBK-R4
The compensation frames are now removed individually
2
as far as the height of the fi nished fl oor.
To do so, take hold of the fl aps on the compensation
frame with both hands and pull upwards (see Fig.: 23).
Legend for Fig.: 23
1
Flaps
Then spread suffi cient GMT or GML lubricant on the sealing
3
rings of the seal insert and the inside of the adaptation
pipes of the basic unit (see Fig.: 24).
Insert MSH Basic-MBK-R4 seal insert completely into the
4
basic unit of the MSH Basic-FUBO-E-SR4 set in concrete
until the fl ange of the seal insert touches the fi nished fl oor
height or the upper edge of the basic unit.
Then strike in the two nail screws on the basic unit with
a hammer and fasten (see Fig.: 25).
Now it is possible to feed in the various connection lines
5
for gas, water, power and telecommunications through
the ducts (see Fig.: 26).
• Consult the supplier before feeding through the
media lines.
• The service sealing elements are applied accord-
ing to the assembly instruction "PolySafe sealing
elements and sleeve caps".
Art. Nr.: 5090032065