Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - Cola TOPFIRE 70 Installations-, Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Inspection
doors
Every 3-4 months clean the inside walls (insulating-refractory) of the combustion chamber using suitable
equipment (brushes) and replace them if necessary.
Every 1800 hours of operation, by means of a message 'SERVICE DUE' the insert signals the need for
extraordinary maintenance (not under warranty), to be performed by qualified personnel who will carry out complete
cleaning and reset the message.
Any knocking or forcing can damage the fume extractor, making it noisy during
operation; therefore it is advisable to have this operation carried out by qualified personnel.
5.5 Cleaning the air flow meter
The air flow meter (it measures the flow of combustion air) installed inside the inlet pipe requires periodical internal
cleaning every 3-4 months, using suitable equipment (blowing compressed air or suitable brushes).
5.6 Cleaning the flue - flue connection
The flue connection must be cleaned at least once a year or whenever necessary depending on stove use and the
type of installation.
Cleaning requires the suction and removal of the residuals in all the vertical and horizontal sections as well as the
bends from the unit to the flue.
It is advisable to also clean the flue every year to ensure proper and safe evacuation of fumes.
5.7 Various checks
All seals fitted on the parts and components involved in maintenance (fume extractors, inspections, exhaust
manifolds, fire door, etc.) must be replaced at the time of the operation.
At the end of the maintenance, check the seals and proper operation of the unit.
For any maintenance or end of season cleaning, COLA recommends contacting an authorized
service center, which will also check the wear on the stove's internal components.
6

MAINTENANCE

6.1
Introduction
Operations on the internal parts of the stove must be carried out by qualified personnel. Contact the nearest
authorized service center.
Make sure the insert is unplugged and cold before carrying out any work on it.