Herunterladen Inhalt Inhalt Diese Seite drucken

Cola TOPFIRE 70 Installations-, Bedienungs- Und Wartungsanleitung Seite 50

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Optional air inlet KIT
A
-
:
solution with connection
on the right side and
flexible pipe downwards
through the base and
final connection located
at the bottom of the
insert compartment.
Power cable
2.4 Fume exhaust
The fumes can be exhausted through a connection to a conventional flue or an external duct with double wall or
insulated pipe.
The fume exhaust connections must guarantee a minimum draft of 10 Pa so that the evacuation of fumes is ensured
in case of a temporary power failure.
- The installer must check the efficiency and state of the flue and its conformity with the
local, national and European regulations.
- Certified pipes and connections with adequate seals guaranteeing their tightness must be used.
- Clean the flue and respective connection at least once a year.
2.4.1 Types of installation
Listed below are definitions and requirements for correct installation of an exhaust flue in accordance with Italian
Standard UNI10683:
FLUE: a vertical duct for collecting and expelling, at an appropriate height
from ground, the fumes coming from a single unit and, where permitted,
more than one.
FLUE technical requirements:
- it must be fumetight, isolated and insulated depending on its use;
- it must have a mainly vertical path with axis deviations <45°;
- it must be at a suitable distance from flammable materials with insulation
or air gap;
- it must preferably have a constant, free and independent round internal
section;
- it is advisable for the flue to have an inspectionable chamber for the
collection of solid materials
- and any condensate, placed under the beginning of the fume duct.
FLUE CONNECTION or DUCT: duct or connection element between the
unit and flue for evacuation of fumes.
DUCT technical requirements: - it must not cross rooms in which the
installation of combustion units is not allowed;
- flexible metal or fibre cement pipes are prohibited;
- the use of counter-sloping elements is prohibited;
- horizontal sections must have an upward slope of at least 3%;
Optional air inlet KIT
B
-
:
solution
with
connection on the right
side and flexible pipe
upwards
and
final
connection located at
the top or side of the
insert compartment.
All the applications must draw the
combustion
air
protection GRILLE complete with
internal net connected to the inlet
flexible
pipe
connection.
This component is not included in
the optional air inlet kit.
Min. distance 0.2 m
50
Optional air inlet KIT
C
-
:
solution
with
connection and pipe-
terminal towards the
rear
of
compartment
the wall converging on
the grille. (outside).
through
a
or
terminal
Antiwind
grille
Flue
Flue
connection
Inspectionable
chamber
Ext. Air inlet
min.100 cm
TOPFIRE 70 – TOPFIRE 80
rear
the
through
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Topfire 80

Inhaltsverzeichnis