Connect the insert power supply.
Within 10 seconds after turning on the power, confirm the selected channel by pressing button P3. The
message UNIT LOADED and then insert status will appear in quick succession. If the message
SEARCHING FIELD appears, tuning was unsuccessful and the procedure must be repeated.
The remote controller display changes according to the status of the insert, or the menu displayed. When idle, the
display shows the following items:
Status indicators
During normal operation, data transmission occurs at regular intervals.
Therefore the remote control displays the insert status with a few seconds delay.
4.2.1
Lighting
Before lighting the insert:
make sure to have read and understood the instructions in the manual;
the hopper must be filled with pellets;
the combustion chamber must be clean;
the brazier must be completely free, clean of any combustion residuals and properly positioned in the
brazier holder;
check the hermetic closure of the fire door and ash pan;
make sure the insert is completely inserted in its compartment and that it is properly electrically powered.
- At first lighting, remove any components that could burn (instructions/label) from the insert firebox.
- Any lightings done after long unit idle periods require the renewal of any pellets that have been inside
the hopper for a long time (in being a damp fuel no longer suitable for combustion) and complete
cleaning of the combustion chamber.
To light the insert press button P3 on the remote control. The message START will appear on the LCD display. This
phase is automatic and is managed entirely by the electronic control, without any possibility of changing the
parameters.
The insert carries out the startup phases in sequence according to the procedure defined by the parameters. If the
fume temperature has not reached the minimum permissible value, the insert goes in alarm status. If the
temperature is reached, after a certain time, the insert goes in work status.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Center.
4.2.2
Work phase
After the startup phase, the insert goes to WORK
mode, which is normal operation.
The heating power can be adjusted with the remote
control. By pressing button P5 the display appears as
shown opposite.
Press P1 and P2 to set the power from a minimum
value of 1 to a maximum value of 5.