If the compartment is not accessible, proceed as follows:
1 - remove the pullout part of the insert from the guides and the fixed base by undoing the 9 guide-fixing screws
each side, after pulling it out completely;
2 - fix the base in the reference compartment with 8 anchors, making sure it is flat-horizontal and perpendicular to
the outer wall;
3 - make connections to the flue A and possible combustion air inlet B (available on request) without forcing the
connection parts on the base;
4 - make the electrical connection and/or ensure that the electric cable is run safely to the external outlet;
5 - after pulling out the telescopic guides from the base, refit the monoblock on them, carrying out the procedure of
step 1 in reverse order;
6 - check the sliding of the pullout part, locking of the latch and operation of the safety
microswitch for the insert's power supply;
9
screws
LH
9
screws
RH
Electrical
connection
The insert has a remote control with display and incorporated ambient probe for measuring the temperature in the
context of the room.
For measuring away from the unit, the installation of a room chronothermostat/thermostat is recommended.
- Installation and assembly must be done by qualified and/or authorized personnel.
- The insert cannot be installed in bedrooms, bathrooms and in general in rooms where
another heating unit is already installed without an independent air inflow.
It is advisable to provide suitable fire-prevention devices for any eventuality.
-
- Do not install the insert in places with an explosive atmosphere.
2.3 Combustion air inlet
A quantity of air at least equal to that necessary for combustion must flow in the room where the insert is installed;
therefore the combustion air necessary to ensure correct operation of the unit must be drawn:
from the room, provided there is a wall air inlet near the insert, communicating with the outside and with a free
area of at least 100 cm² suitably protected externally by a grille;
or with connection directly to the outside through an appropriate optional assembly to be installed on the rear
side of the base, consisting of a small manifold, a flange with 50 mm circular mouth and a 1.5 m (max.) flexible
pipe. The end of the flexible pipe must be placed on a connection to the outside provided with a protection grille
to prevent any obstructions.
DETAIL B
B
RH side
49
TOPFIRE 70 – TOPFIRE 80