Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Assistance Service - V2 AXIL Serie Bedienungsanleitung

Nicht umkehrbarer elektromechanischer antrieb für flügeltore
Vorschau ausblenden Andere Handbücher für AXIL Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 53
PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED
The automation device should not be used until installation, as specified in "Testing and start-up", has been performed.
It should be remembered that the device does not compensate for defects caused by improper installation, or poor
maintenance, thus, prior to proceeding with installation, ensure that the structure is suitable and meets current standards
and, if necessary, perform any structural modifications aimed at the implementation of safety gaps and the protection or
segregation of all crushing, shearing and transit zones, and verify that:
• The gate has no friction points, either during closing or opening.
• The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.
• The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the
size of the motor reducer itself.
• The support on which the automation device will be fixed is solid and durable.
• The mains power supply to which the automation device is connected has a dedicated safety earthing system and
differential breaker with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than
or equal to 3 mm).
Warning: The minimum safety level depends on the type of use; please refer to the following outline:
Type of activation commands
Man-present command
Remote control and closure in view
(e.g. infrared)
Remote control and closure not in view
(e.g. radio)
Automatic control
(e.g. timed closure control)
Group 1 - Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this
type are gates inside business premises, where the sole users are employees, or a part of them who have been suitably
informed.
Group 2 - Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example
of this may be a company gate that accesses onto a public street, and which is only used by employees.
Group 3 - Anyone can use the automated closure, which is thus located on public land. For example the access gate to a
supermarket or an office, or a hospital.
Protection A - Closure is activated by means of a control button with the person present, i.e. with maintained action.
Protection B - With the person present, closure is activated by a command controlled by means of a key-switch or the
like, in order to prevent use by unauthorised persons.
Protection C - Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the
impact force must fall within a curve established by the regulations.
Protection D - Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active
on just one side or on both sides of the door or gate.
Protection E - Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person,
and installed in such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be
active within the entire "danger zone" of the gate. The Machinery Directive defines "Danger Zone" as any zone surrounding
and/or near machinery where the presence of an exposed person constitutes a risk to the health and safety of that person.
The risk analysis should take into consideration all danger zones for the automation device, which should be
appropriately protected and marked.
In a clearly visible area, apply a sign with information identifying the motorised door or gate.
The installer should provide the user with all the information relating to automatic operation, emergency opening
and maintenance of the motorised door or gate.

TECHNICAL ASSISTANCE SERVICE

For any installation problem please contact our Customer Service at the number +39-0172.812411 operating Monday to
Friday from 8:30 to 12:30 and from 14:00 to 18:00.
Group 1
Informed people
(use in private area)
A
C or E
C or E
C and D or E
12
Closure use type
Group 2
Informed people
(use in public area)
B
C or E
C and D or E
C and D or E
Group 3
Informed people
(unlimited use)
Not possible
C and D or E
C and D or E
C and D or E

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Axil-fcAxil-ecdAxil-120vAxil-230vAxil-24v

Inhaltsverzeichnis