Herunterladen Inhalt Inhalt Diese Seite drucken

Ordering Parts; Devilbiss Customer Service Contact Information; Ordering Replacement Parts; Parts List - DeVilbiss iGo Series Servicehandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

O R D E R I N G I N F O R M AT I O N A N D PA R T S L I S T

ORDERING PARTS

DeVilbiss Customer Service Contact Information

Customer Service (USA): 800-338-1988 / 814-443-4881, cs@DeVilbissHC.com
International Department: 814-443-4881, DHCinternational@DeVilbissHC.com
Europe: +49 (0) 621-178-98-0

Ordering Replacement Parts

Order parts and literature from your DeVilbiss provider. To expedite the process, be prepared to provide the following information:
Account and ship-to numbers
Ship-to address
Part numbers and/or descriptions
Quantity required
Unit catalog number
Unit serial number
Hours of operation

PARTS LIST

ACCESSORIES

306DS-651
AC Charger/Adapter
306DS-652
DC Adapter
306D-413
Rechargeable Battery Pack
306DS-627
Humidifier Kit (1 each remote stand and
humidifier adapter)
Salter Labs 7600
Bubble Humidifier
or equivalent
444-507
Elbow Humidifier Adapter Kit
306DS-635
Deluxe Rolling Carry Case
306DS-626
Detachable Wheeled Cart
A-306-1 & A-306-2
Instruction Guide
306CH
iGo Battery Charger
306DS-655
iGo Accessory Bag
POWER CORDS
306DS-601
USA Power Cord
306DS-602
Continental Europe Power Cord
306DS-603
UK Power Cord
306DS-604
Australia Power Cord
306DS-605
China Power Cord
FILTERS
306DS-611
Air Filter
PV5LD-651
Final Bacteria Filter
TOOLS
R217P62 &
Oxygen Analyzer
R218P12
303DZ-637
Pressure Test Assembly
PVO2D-601
Pressure Vacuum Gauge
444-501
Service Kit
COMPONENTS (currently available)
306DS-633
303DZ-628
306DS-606
306DS-631
306DS-632
PV5LD-617
306DS-615
306DS-609
306DS-616
306DS-612
4650D-609
306DS-654
There are many types of humidifiers, oxygen tubing and cannulas/
masks that can be used with this device. Certain humidifiers and
accessories may impair the device's performance. Use only standard
nasal cannula capable of supporting a minimum flow rate of 10 LPM
with PulseDose delivery. Do not use pediatric (low-flow) nasal cannula
or mask with PulseDose delivery. A mask or any nasal cannula can be
used with continuous flow delivery and may be sized according to
your prescription as recommended by your homecare provider who
should also give you advice on the proper usage, maintenance, and
cleaning.
NOTE–The oxygen supply accessory (patient tubing) shall be
equipped with a means that in case of fire stops the delivery of
oxygen to the patient. This means of protection should be located as
close to the patient as practicable and not adversely affect the
delivery of oxygen during normal use in either continuous flow or
PulseDose modes of operation.
15
Base Kit
Cover Screws
Carton w/ Shipping Inserts
Front Cover Kit
Rear Cover Kit
Hour Meter
Control Panel
Motor Mount Kit
Intake Silencer/Filter
Exhaust Muffler
Battery Bumpers (push-in feet used in battery
compartment)
Replacement Feet Kit
LT-2044

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Igo a-306-2Igo a-306-1

Inhaltsverzeichnis