switch to lower level.
In the fan mode, only the fan motor works. The display shows only the ambient temperature. The
setting temperature cannot be changed. This unit can blow the air to various angles.
4.
FAN button: the fan may operate in the following manners:
In the cooling mode (except the sleep mode) and fan mode: high→low→high→ and so on.
Switching between the cooling, fan and drying modes: maintain the fan speed of the previous mode.
5.
TIMER button:
After starting the unit, press the Timer button to enter timed shutdown. After shutdown the unit,
press this button to enter timed start. In the meanwhile, the timer indicator will illuminate.
Press the Timer button to enter the timing function (timed start/timed shutdown). Adjust the up or
down button to set the timing time. The time will cycle in the order of 1 2 3 ......24 0 1
hours or 24 23 22 ......1 0 24 hours. The adjustment time of the timing function is relative
time.
After the time is set, once the timed start time is reached, the unit will start. In the meanwhile,
the timer indicator will extinguish and the ambient temperature will be showed on the display.
On/Off operations caused by the button or remote control will clear all timing settings.
Once the timing is set, if the timer button is pressed once, it is possible to query the remaining
start/shutdown time. If the timer button is pressed twice continuously within 5s, it is possible to cancel
timing.
Remote control
The operation instructions of the buttons of this simple remote control are as follows:
1. Power button: press this button to turn on/off the unit;
2. Timer button: upon shutdown, press this button to set timed start; upon start, press this button
to set timed shutdown.
3. High button: press this button to allow the unit to operate in the high fan speed state
(except in the dry and sleep modes);
4. Low button: press this button to allow this unit to operate in the low fan speed
state;
5. Up button: press this button to increase the temperature and timing value;
6. Down button: press this button to decrease the temperature and timing value;
7. ℃ — F button: press this button to switch between the Celsius degree and
Fahrenheit degree;
8. Cool button: press this button to set this unit to operate in the cooling mode;
9. Fan button: press this button to set this unit to operate in the air supply mode;
10. Dehumidifying button: press this button to set this unit to operate in the dry mode;
11. Sleep mode: press this button to set this unit to operate in the sleep mode.
Protection functions:
1.
Anti-freeze protection function:
In the cooling mode, when the compressors operates continuously for more than 10 minutes, if the
pipe temperature Tp is less than or equal to 2℃ continuously for 20 seconds, the compressor
and water spraying motor turn off, other loads operate and the display shows E4, the unit initiates
the anti-frost protection function and the buttons are inactive (except the OFF button). Once the pipe
temperature rises to exceed or equal 8℃, the protection is relieved, the original status is restored
and the unit meets the requirements for 3-minute delay protection of the compressor.
2.
Full water protection function:
When the water in the water tray exceeds the alarm level, the unit will alarm automatically and the full
water indicator illuminates. In this case, you need to drain the condensate in the unit; otherwise, the
unit will shut down automatically after the buzzer gives off 5 beeps. (For more information about the
24