2 Product Description

2 Product Description

2.1 Designated Use

2.2 Use contrary to the designated use

2.3 Technical Data

Ambient temperature of welding
Transport and storage
Relative humidity
Control device rating
Tab. 1
General data
Type of voltage
Polarity of the electrode
Wire types
Type of use
Voltage rating
Protection type of the machine side
connections
Shielding gas (DIN EN ISO 14175)
Tab. 2
General torch data according to EN 60 974-7
Type
Type of
cooling
ROBO WH
241D
liquid
Tab. 3
Product specific torch data as laid out in EN 60974-7
EN - 4
The liquid-cooled welding torch system WH, WHPP must be used for robot and
automatic application. Designated use also includes the observance of the
prescribed operating, maintenance and servicing conditions.
Any use other than that described under "Designated Use" is considered
contrary to the designated use. Unauthorized conversions or power increase
modifications are not allowed.
- 10 °C to + 40 °C
- 25 °C to + 55 °C
up to 90 % at 20 °C
1A AC / 250V AC
DC direct voltage
Usually positive
commercially available round wires
automatic
Peak value of 141 V
IP2X (EN 60 529)
CO
1
Load
Duty
cycle
CO
M21
2
A
A
%
320
280
100
and mixed gas M21
2
ø
Wire
Gas
Cooling data
flow
Cooling
capacity
min
mm
l/min
W
0.8 - 1.2 10 - 20 800
WH and WHPP
flow
Flow pressure
min
min.
max.
l/min
bar
bar
1
1.5
3.5

Werbung