Wired networking
If the device should be integrated into the network via
Ethernet, a suitable network cable with RJ45 plug must be
routed to the device.
The network cable must have sufficient dielectric strength
and be suitable for common routing with live conductors.
MENNEKES recommends using Ethernet cables
cat. type 7a or higher.
Fig.: 13. Connecting network cable
f Make sure that the bending radius of the network cable
used is not too low.
f Connect the plug (2) of the network cable to the net-
work socket of the HCC 3s (1).
14

5.6.3 Creating tariff-switching signal

For operating the device in mode "network control", the
device must be connected to, for example, a ripple control
receiver.
The tariff-switching signal is connected to the HCC 3 with a
connector.
„ To activate the off-peak tariff (NT), the tariff-switching
signal must be present at the input of the HCC 3s.
„ If the main tariff (HT) is active, no tariff-switching signal
must be present at the input of the HCC 3s.
Fig.: 14. Connect tariff-switching signal
f Strip the control line.
f Connect phase to terminal A and neutral conductor to
terminal B of the plug connector (2).
Terminals
Description
A
Phase for tariff-switching signal 230 V AC
B
Neutral conductor for tariff-switching signal
230 V AC
f Insert the plug connector into the corresponding con-
nector strip (2) on the HCC 3 (1).
f Connecting the external device according to the manu-
facturer's instructions.
1
2
3
A B