Mirror contact error
15
Invalid device time
Home Manager
16
connection error
30
Device startup
Internal test not
31
passed
32
HMI not connected
Badly plugged
50
cable
51
Wrong cable
Communication
52
with the vehicle
interrupted
100 (only
with operat-
ACU communica-
ing mode
tion error
"SCU")
101 (only
with operat-
Not polled by ACU
ing mode
"SCU")
102 (only
with operat-
Maintenance
ing mode
"SCU")
103 (only
with operat-
Disabled
ing mode
"SCU")
255
Unknown error
32
Contactor sticks or not
tightened
Mirror contact defective
Invalid or no system time
No connection to the
Energy Manager
Device does not start or
is in the faulty state after
startup
Device does not start
LED information field is
dark and charge not pos-
sible
Charging not possible
Charging not possible
Charging not possible
Device does not receive
data from the ACU
No connection with RS-485
bus
Maintenance is carried out
in the service interface of
the ACU
The charging point has
been deactivated in the
service interface of the
ACU
f Check contactor and replace if necessary.
f Acknowledge the fault.
f Check mirror contact and replace if necessary.
f Acknowledge the fault.
Î"6.6 Time synchronisation"
f Check network and Energy Manager settings in the ser-
vice interface.
f Check the LAN / WLAN connection.
f Disconnect the device from the mains for three minutes
and restart it.
f Acknowledge the fault.
f Disconnect the device from the mains for three minutes
and restart it.
f Acknowledge the fault.
f Check HMI cable connection and reestablish if neces-
sary
f Acknowledge the fault.
f Disconnect charging cable and plug in again.
f Check charging cable and replace if necessary.
f Disconnect the device from the mains for three minutes
and restart it.
f If the LED info field is permanently lit:
Acknowledge the fault.
f Check charging cable and replace if necessary.
f Check the configuration of the ACU.
f Check RS-485 bus.
f Disconnect the device from the mains for three minutes
and restart it.
f Reinitialize the RS-485 bus.
As of HCC 3 software version 1.08, the RS-485 bus is ini-
tialized automatically after a certain time and the fault is
eliminated.
Once the maintenance is completed, the error code will
no longer be displayed.
f Navigate to "Main page" > "Setup" > "SCU-Setup" in the
service interface of the ACU.
f Deactivate "SCU Disabled".
 Installation manual MENNEKES ACU / SCU