Herunterladen Inhalt Inhalt Diese Seite drucken

Mennekes Amton Premium Installationsanleitung Seite 43

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Interior view of lower enclosure part
Fig.: 6. Interior view of lower enclosure part (example)
1.
Energy meter
2.
MCB (optional with shunt release)
3.
Actuating element for multi-function button
4.
Charging contactor point
5.
Phase sequence relay
6.
Cable glands
7.
Control (HCC 3)
8.
RCD
1)
9.
Power adapter
10. Connection terminals for mains connection
Optional
1)
HCC 3
Fig.: 7. HCC 3 (example)
1.
2.
3.
4.
5.
6.
7.
1)
8.
1)
9.
The HCC 3 provides five operating modes that can be
changed even during operation depending on the configu-
ration.

Plug strip for tariff switching
Status LEDs
Network connection (RJ45)
Plug strip, power supply 12 V DC
Plug strip RS-485 bus
Plug strip for charging socket
Plug strip for S0 counter
Plug strip for front panel
Plug strip for low voltage signal 230 V AC
Operating manual AMTRON Xtra (E/R), Premium (E/R/W)
"5.1 Functional description of the operating modes"
The availability of operating modes and functions
depends on the equipment and the configuration
of the device. The configuration is carried out via
an Internet browser in the service interface.
EN
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis