11 Technical Data

General data
Dimensions
Weight
Version (switching valves)
Version (AV-EP)
Operating temperature range
Storage temperature range
Ambient operating conditions
Relative humidity
Degree of contamination
Protection class according to EN
60529/IEC529
Protection class to control cabinet
Mounting orientation
Use
Pneumatics
Medium
Control pressure
Operating pressure
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15°C below the ambient and medium
temperatures and must not exceed 3°C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS.
Media temperature
Nominal flow
Electronics
Electronics power supply
Valve power supply
Valve inrush current
Current at maximum configuration
(multipole)
Multipole plug (25-pin)
Multipole plug (44-pin)
Rated current for both 24 V power
supplies (bus coupler)
Standards and directives
DIN EN 60204-1 "Safety of machinery – Electrical equipment of machines – Part 1:
General requirements"
EN 61000-6-2: Electromagnetic compatibility (EMC) – Part 6-2: Generic standards
– Immunity for industrial environments
EN 61000-6-4 Electromagnetic compatibility (EMC) –
Part 6-4: Generic standards – Interference emission for industrial environments
DIN EN ISO 4414 Pneumatic fluid power - General rules and safety requirements
for systems and their components
Only use PELV electric circuits in accordance with EN 60204-1.
Always establish the power supply using a safety isolation transformer in
accordance with IEC 61558-1/IEC 61558-2-6 (EN 61558-1/EN 61558-2-6).
Equivalent solutions are permitted.
Make sure that the supply voltage for the power pack is always less than
300 V AC.
Further technical data can be found in the pages for individual components in our
online catalog (www.aventics.com/pneumatics-catalog).

12 Spare Parts and Accessories

Information on spare parts and accessories can be found in the online catalog
(www.aventics.com/pneumatics-catalog).
Depending on the configuration, see the
AVENTICS online catalog
Depending on the configuration, see the
AVENTICS online catalog
Spool valve, elastic seal
Externally piloted pressure regulator
ϑ
-10°C to 60°C
U
-25°C to 80°C
Max. height above sea level: 2000 m
95%, non condensing
2
IP65 with assembled connections
IP 54 with direct connection
IP 65 with transition plate
Any
Only in closed rooms
Compressed air
3 bar/8 bar
-0.9 bar/10 bar
40 μm
3
0 – 5 mg/m
ϑ
–10°C to +60°C
M
q
AV03: 300 l/min; AV05: 700 l/min
v
24 V DC ±25%
24 V DC ±10%
50 mA
24 x 50 mA
40 x 50 mA
Maximum 24 coils
Maximum 40 coils
4 A