Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating
plate specifications. If using an extension cord, it must be water-resistant.
Filter cleaning:
The filters should be cleaned when the manometer is in the red field.
Cleaning the filter:
During filter cleaning, the machine should be running and the hose removed from the
suction pipe.
1. Press the connector sleeve against the black stop lug on the exhaust duct or
against the floor in order to produce maximum negative pressure in the cyclone.
Open and close the hatch on the side 3-6 times. Air flows into the machine and
cleans the filter by creating a reverse pulse.
2. Turn off the machine and let the material fall down. Reconnect the suction pipe.
3. Start the machine.
4. If the manometer needle is back in the green zone, work can continue. If it
remains in the red zone, the cleaning process should be repeated. Some actions
(such as those that restrict air flow) may cause the manometer to display a high
value (needle in the red zone). The machine should never be used continuously
when the meter is in the red zone, as there is a risk of overheating. The transition
from the green zone to the red zone takes place at 15.5 kPa.
DC 1800H/DC 2800H, Art.nr. 9497-G
28