Emptying
• The container underneath the cyclone should be emptied when about 2/3 full.
• You can use the machine with or without a plastic bag in the container.
• You must clean the filters before replacing the plastic bag.
• The plastic bag must be sealed as soon as it is removed from the container.
• Only use original bags as there must be no creases around the edge of the
container. This tight seal prevents the bag from being suctioned up.
The container underneath the cyclone should be emptied when it is filled to about 2/3
or contains a maximum of 20 kg.
When emptying, carefully release the two fasteners, one at a time, so that dust is not
stirred up unnecessarily. After lowering the container (on DC 2800 H) or lifting the
upper part of the machine (on DC 1800 H), turn on the dust extractor again so that any
air borne particles are sucked into the filter cyclone. The container can now be
completely removed from the machine. Carefully remove the entire bag from the edge
of the container and seal it immediately. Then fit a new plastic bag in the container,
carefully folding the open end over the edge of the container. Ensure that the plastic
bag is intact with no visible creases. Carefully put the container back under the
extractor unit. Attach the two fasteners, switch off the machine, re-attach the container
and check for any leaks.
For best results:
• When attaching the plastic bag, ensure that there is no air between the plastic bag
and the container.
• Ensure that air does not enter between the container and the bag when the machine
is running.